核心优势

Featured Products

Zone 2 air compressor is a special air compressor used in coal mines and other mines to improve the safety performance of air compressors. Zone 2 air compressor is used for all electrical systems, switches, etc. of air compressor motors, control system electrical, display screens, etc. The parts of gas generator that may cause sparks must be explosion-proof. Simply put, the explosion-proof air compressor on AC alternator is an air compressor that cannot cause an explosion. Air compressor explosion protection for lighting tower is not only about motor explosion protection, electrical explosion protection for resistive load bank is more important, you think, if underground coal mines catch fire or explode due to air compressors, you only need motor explosion protection is not enough. There are few domestic manufacturers that can produce explosion-proof air compressors, and they need to have certificates such as "Safety Mark Certificate" to produce. The model, displacement, pressure, etc. of the air compressor must have a unique certificate. Coal mines or chemical systems are more stringent and may require explosion isolation. This is a diesel water pump technology to prevent the spread of explosions.
Gas generator sets use gas as their fuel. These include 3-phase gas Generators, LNG, and LPG generator sets, among others.
Kingway offers a comprehensive selection of high-quality generator sets at competitive prices, solidifying our position as a leading company in the industry. Our range of generator sets caters to a wide variety of applications, including farms, agricultural industries, data centres, hospitals, manufacturing centres, quarries, mines, telecommunications, hotels, and rural homes. A generator set typically comprises an engine for providing kinetic energy, a generator for producing current, and a control system. Our product range includes generators of varying sizes and types, such as diesel, gas, gasoline, wind, solar, hydroelectric, and coal-fired generators. Additionally, generators are categorized as either AC or DC based on the type of electric energy they produce.
The gas generator set use the gas as its fuel, include 3 Phase Gas Generator, LNG, LPG generator set etc. Kingway Gas Power Department has been committed to the research and development of gas engines, has developed the controller ECU and generator radiator suitable for different gas fuels, has completely independent intellectual property rights. We can not only provide the whole gas engine, but also provide 3 phase diesel generator modification service and design, manufacture
Gas generator sets utilize gas as their fuel, encompassing 3-phase gas Generators, LNG, and LPG generator sets. The Gas Power Department at Kingway has been dedicated to the exploration and advancement of gas engines and has designed the ECU controller and generator radiator suitable for various gas fuels with completely independent intellectual property rights. They can furnish not only the complete gas engine but also offer modification, service, and design for 3-phase diesel generators, as well as the development and installation of the gas supply system (gas skid station). With their robust technology, any type of diesel engine and AC alternator can be effectively converted into a single or dual-fuel gas engine, exhibiting no fundamental performance distinctions when compared to the original machine, and can be tailored to match the working and environmental conditions, leading to superior operational performance than the original machine. 3 Phase Gas Generators are also gaining popularity in overseas markets.
The gas generator set use the gas as its fuel, include 3 Phase Gas Generator, LNG, LPG generator set etc. Kingway Gas Power Department has been committed to the research and development of gas engines, has developed the controller ECU and generator radiator suitable for different gas fuels, has completely independent intellectual property rights. We can not only provide the whole gas engine, but also provide 3 phase diesel generator modification service and design, manufacture
Hazardous area products manufactured for safe installation in explosive atmospheres and hazardous area zones and categorized according to ATEX as follows: ① Zone 0 Group II Category 1G The presence of explosive atmospheres is continuous, frequent or for long time periods ② Zone 1 Group II Category 2G The presence of explosive atmospheres is intermittent in normal operation (likely) ③ Zone 2 Group II Category 3G The presence of explosive atmospheres is occasional or for short periods (never in normal operation).
Rig Safe Equipment include Rig safe diesel generator, Rig Safe air compressor etc can not used in hazardous area, are commonly used in the safe area of the O&G Platform or Facility. The units require added safety features though not as stringent as units which are used in the Hazardous area zone 2.
Gas generator set use the gas as its fuel, include Natural Gas, Biogas,LNG, LPG etc   Kingway Gas Power Department has been committed to the research and development of gas engines, has developed the controller ECU suitable for different gas fuels, has completely independent intellectual property rights.
Kingway Engine Conversion Department Kingway Engine Conversion Department has been committed to the research and development of gas engines, has developed the controller ECU suitable for different gas fuels, has completely independent intellectual property rights.
Kingway Marine diesel generator sets generally include commonly use marine diesel generator sets and emergency marine diesel generators. The marine diesel generator can be divided by function: ordinary type generating set, automatic type generating set, monitoring type generating set, automatic switching type generating set, automatic combination type generating set. Marine generator sets are widely used and can be used as a main power supply or as a backup power supply.
CKD (Complete Knocked Down) and SKD (Semi Knocked Down) generators are disassembled into parts rather than pre-assembled. CKD saves on import tax, reduces facility investment, transportation costs, and assembly expenses while enhancing assembly ability, productivity, and price competitiveness, while expanding the supply scope. We offer a range of CKD/SKD solutions from various brands, including diesel engines (Cummins, Perkins, Deutz, MTU, Yanmar, Doosan, Volvo), alternators (Stamford, Leroy Somer, Mecc Alte, Kingway Brand Alternator), control systems (Deepsea, ComAp, Smartge, Kingway), base frames, and other assembly-related components.

Tell me what you need