Rig Safe Generator

Featured products

The diesel engine propels the generator to convert diesel energy into electrical energy. Within the diesel engine's cylinder, the clean air, filtered by the air cleaner, thoroughly combines with the high-pressure atomized diesel fuel released from the fuel injection nozzle. As the piston moves upward, the volume decreases, leading to a rapid rise in temperature, ultimately reaching the ignition point of the diesel fuel. The ignited diesel results in a vigorous combustion of the mixed gas, causing a rapid expansion of volume which, in turn, propels the piston downward, generating mechanical work. Additionally, we provide Resistive Load Banks, 3-phase diesel generators, and various other types of generating sets.
For use in Hazardous Area (Zone 2), diesel-operated generator sets installed in the DNV-approved 2.7-1 Skid frame container, generating 400KVA @ 0.8 power factor, 400VAC, 3-Phase +Neutral, 50Hz/60Hz Output.
Zone 2 air compressor is a special air compressor used in coal mines and other mines to improve the safety performance of air compressors. Zone 2 air compressor is used for all electrical systems, switches, etc. of air compressor motors, control system electrical, display screens, etc. The parts of gas generator that may cause sparks must be explosion-proof. Simply put, the explosion-proof air compressor on AC alternator is an air compressor that cannot cause an explosion. Air compressor explosion protection for lighting tower is not only about motor explosion protection, electrical explosion protection for resistive load bank is more important, you think, if underground coal mines catch fire or explode due to air compressors, you only need motor explosion protection is not enough. There are few domestic manufacturers that can produce explosion-proof air compressors, and they need to have certificates such as "Safety Mark Certificate" to produce. The model, displacement, pressure, etc. of the air compressor must have a unique certificate. Coal mines or chemical systems are more stringent and may require explosion isolation. This is a diesel water pump technology to prevent the spread of explosions.
Kingway Clip On ( Top mounted ) Reefer Diesel Engine Generator Set
Kingway offers a wide selection of high-quality clip-on generators at affordable prices. As a leading company in the industry, we supply a variety of generator sets for different applications, including farms, the agricultural industry, data centres, hospitals, manufacturing centres, quarries, mines, telecommunications, hotels, rural homes, and more. The diesel generator will start when the battery's state of charge (SOC) falls below a certain predefined value (low-switch). If the diesel generator is already running, it will stop when the batteries are recharged to a predefined level (high-switch) or if the wind turbine's energy production exceeds the load demand.
Diesel generator sets powered by diesel for use in a hazardous area (Zone 2) installed in a DNV-certified 2.7-1 skid frame container producing 30KVA @ 0.8 power factor, 400VAC, 3-phase +Neutral, 50Hz output.

Tell me what you need